LVC_TP_DecayRate
This parameter determines how fast the display value of the "dB TP" display of LVC decreases when the volume decreases. Units are dB per second.
The value 0 means "instantanteous decrease", i.e. the peak display immediately follows the volume. Positive values mean that the display becomes less jumpy. Only one decimal digit is significant. The dot (.) serves as decimal separator.
The parameter is defined inside the loudness set for all applications that use LVC, but it can be overridden for specific applications.
Requires LVC version 1.0.63.0 or higher.
Possible values: Non-negative floating-point numbers
Default value: 0